CRYO POSITIONING SYSTEMS CONTROLLER (CPSC)

A modular controller system for Cryo & Nano Positioning products of JPE

CONFIGURATION

FEATURES

 Cabinet houses up to 6 modules
 Includes power supply for all available modules
 Includes PC interface for external control
 Suitable for all Cryo & Nano Positioning systems
 19″ rack mountable desktop case
 Support for multiple cabinets
Available for 115VAC or 230VAC mains

DESCRIPTION

The Cryo Positioning Systems Controller is a modular controller system for all JPE Cryo Actuator products. This controller consist of a 19” desktop Base Cabinet (CAB) and can fit up to 6 function specific modules (brochures for each available module can be found below). The CAB includes a Power Supply Unit and PC Interface for interfacing with a desktop computer or laptop (Basedrive or Servodrive). Control software for PC (Windows OS) can be downloaded for free on this page (see section below).

Controller Software & User Manuals
CPS Cabinet Serial IDUser Software version
(click to download zip file)
User Manual version
(click to download pdf file)
1038E201610-XXX
1038E201605-004
1038E201605-002
1038E201605-001
1038E201605-000
1038E201506-003
v5.2b (Windows OS)1036_MAN03_R05 (Hardware)
1036_MAN04_R03 (Software)
1038E201605-003v5.1b (Windows OS)1036_MAN03_R02 (Hardware)
1036_MAN04_R01 (Software)
1038E201506-002
1038E201506-001
1038E201503-XXX
1038E201410-002
1038E201410-001
1038E201410-000
v5.0 (Windows OS)1036_MAN02_R02
1038E201410-004
1038E201406-XXX
v4.0 (Windows OS)1036_MAN02_R01
1038E2013MM-XXX
3057EYYYYMM-XXX
v2.3 (Windows OS)1036_MAN01_R01
(no serial? click here to contact JPE!)

CABINET AND AVAILABLE MODULES

CPSC with CADM2, PSM and MCM

Base Cabinet (CAB)

19” desktop Base Cabinet (CAB) and can fit up to 6 function specific modules.

Houses up to 6 modules
Includes power supply for all available modules
Includes interface for external control via a PC
Suitable for: CADM(2), OEM2, PSM and MCM
19″ rack mountable desktop case
Support for multiple cabinets
Available for 115VAC or 230VAC mains

Show CAB specifications >
specsunitCAB-115CAB-230
Number of slots-6
Mains voltageVAC115230
Mains frequencyHz6050
Power consumption (max)W260
Power supply cable connector-USEU
Power supply cable lengthm2.0
PC Interface connection-USB Type B female
PC Interface cable-USB A plug to B plug
PC Interface cable lengthm3.0
Supported mounting options-19" / 3U rack mountable
Mass (without modules)grams6500
Dimensions (LxHxD)mm470 x 140 x 300
CADM

Cryo Actuator Driver Module (CADM)

Module for driving up to 3 Cryo Linear Actuators (CLA) by generating a high voltage setpoint profile.

3 serial output channels
Quadratic set point profile to reduce vibrations
Temperature dependent setpoint compensation
Short circuit and overcurrent protection
Thermal overload protection
Status LEDs on front panel
Fits in Cryo Actuator Base Cabinet (CAB)

Show CADM specifications >
specsunitCADM
Output channels-3 (serial operation)
Compatible with-CLA
Power supply via-CAB-115 or CAB-230
Output voltage (per channel)V-20 … +130
-Floating output*
Frequency rangeHz1 … 600
Step size range%0…100 of max output
Output connector-LEMO EPG.1B.303.HLN
Control (via PC)-Basedrive
Control (stand-alone)-Manual Control Module (MCM)
Massgrams850
Dimensions-3U / 14HP
*Reference must not be connected to common ground (!)
CADM2

Cryo Actuator Driver Module 2 (CADM2)

Module for driving one Cryo Linear Actuators (CLA) by generating a high voltage setpoint profile.

Quadratic set point profile to reduce vibrations
Temperature dependent setpoint compensation
Analog input available (for external DAQ system)
Short circuit and overcurrent protection
Thermal overload protection
Status LEDs on front panel
Fits in Cryo Actuator Base Cabinet (CAB)

Show CADM2 specifications >
specsunitCADM2
Output channels-1
Compatible with-CLA
Power supply via-CAB-115 or CAB-230
Output voltage (per channel)V-20 … +130
-Floating output*
Frequency rangeHz1 … 600
Step size range%0…100 of max output
Output connector-LEMO EPG.1B.303.HLN
External (analog) Input rangeV-10 … +10V
-Output frequency and direction as function of input voltage
External (analog) Input connector-BNC
Control (via PC)-Basedrive, Servodrive or Flexdrive
Control (stand-alone)-Manual Control Module (MCM)
Massgrams850
Dimensions-3U / 14HP
*Reference must not be connected to common ground (!)
OEM2

Optical Encoder Module 2 (OEM2)

The Optical Encoder Module 2 (OEM2) has 3 inputs for Cryo Optical Encoders (-COE option).

3 input channels (simultaneous readout)
Suitable for all products with the -COE option
Reduced laser power, minimize dissipation COE
Counter data available as Quadrature AB output
Status LEDs on front panel
Fits in Cryo Actuator Base Cabinet (CAB)

Show OEM2 specifications >
specsunitOEM2
Input channels-3 (simultaneous readout)
Compatible with-COE
Counter range--2^17 … (2^17)-1
Counter type-Dual edge, bi-directional
Wavelengthnm1310
Laser output powerµ W< 5
Input connector-FC/APC narrow key, female
External output-Quadrature AB* (5[V] TTL)
External in-/output connector-Sub-D, 25p, male
Control (via PC)-Basedrive, Servodrive or Flexdrive
Power supply via-CAB-115 or CAB-230
Massgrams850
Dimensions-3U / 14HP
* OEM2 requires an external direction signal as input (5V TTL).
User has to supply this signal to the External in-/output connector
PSM

Piezo Scanning Module (PSM)

Module for driving up to 3 piezo stacks individually by using 3 separate voltage amplifiers.

 A/B topology voltage amplifier
 3 independent high voltage output channels
 High bandwidth, low noise outputs
 Over temperature protection
 Current protection
 Status LEDs on front panel
Fits in Cryo Actuator Base Cabinet (CAB)

Show PSM specifications >
specsunitPSM
Output channels-3 (parallel operation)
Amplifier topology-A/B
Input voltage rangeV-10 … 10
Voltage GainV/V15 ± 1%
Output voltage range (nom)V-150 … 150
Output voltage range (max)V-180 … 180
Output noise (DC-50kHz)mVpp≤3
Output currentmA≤ 100
Capacitive loadµ F≤5
Bandwidth (Vout < 10Vpp, 100nF load)Hz5000
Bandwidth (Vout < 300Vpp, 100nF load)Hz1000
Dynamic rangedB≥ 103.5
Slew rate (100nF load)V/ µ s10
Output offset (static)mV≤5
Non-linearity (full scale)%≤0.05
Sensitivity (dgain/dVin)1/V0.015
Input impedancekΩ100
Input connector-BNC
Output connector-LEMO EPG.1B.303.HLN
Over temperature protection-Automatic Off/On
Current protection-Fuse 100[mA]
Power supply via-CAB-115 or CAB-230
Control (via PC)-Flexdrive
Massgrams1550
Dimensions-3U / 14HP
PSM Input Limiter (PSMIL)

PSM Input Limiter (PSMIL)

Input Limiter for the Piezo Scanning Module (PSM). Input voltages will be limited to a projected PSM output voltage of -20[V] to +130[V].

 Signal conditioner with hard limiting action
 3 input channels
 Suitable for CPSHRx-S, CTTPSx-S, CHPS-S-COE

Show PSMIL specifications >
specsunitmintypmax
Limiting Style-Discontinuous
Input VoltageV-10-10
Output Voltage*V-1.33-8.66
Output Noise µVrms--300
Large Signal Bandwidth (-3dB) within limit range (10Vpp)kHz0-65
Optimized for large signal frequencies with limiting actionkHz0-5
Non-linearity within limit range%--0.2
Input ImpedancekOhm-100-
Power supply via-100-240VAC Wall adapter
Power dissipationW-1.5-
Stabilisation Time after power ons--5
Massgrams310
Dimensions (LxHxD)mm108,5 x 30 x 80,5
For use with-PSM
* when connected to a PSM this translates to a PSM output voltage range of -20[V] to +130[V]
MCM

Manual Control Module (MCM)

Manual operation of up to 3 Cryo Actuator Driver Modules (CADM(2)).

 Manual control of up to 9 Cryo Actuators
 External Control input selectable
 Display with status information
 Adjustment of direction, step size, frequency
Fits in Cryo Actuator Base Cabinet (CAB)

Show MCM specifications >
specsunitMCM
Compatible with-CADM, CADM2
Output channels-CADM: 3x3 max. (serial operation)
CADM2: 3x1 max. (serial operation)
Power supply via-CAB-115 or CAB-230
Selectable frequency rangeHz1 … 600
Selectable step size range%0…100 of max output CADM(2)
Massgrams800
Dimensions-3U / 28HP

Ordering Information

CAB-115 Cryo Actuator Base Cabinet, 115 VAC (mains input)
CAB-230 Cryo Actuator Base Cabinet, 230 VAC (mains input)
CADM Cryo Actuator Driver Module (3 axes, sequential, Basedrive only)
CADM2 Cryo Acutator Driver Module (single axis, Basedrive, Servodrive and Flexdrive)
PSM Piezo Scanning Module (3 axes, parallel operation, Flexdrive only)
PSMIL PSM Input Limiter
OEM2 Optical Encoder Module (3 axes parallel, Basedrive, Servodrive and Flexdrive)
MCM Manual Control Module (up to 9 axes selectable, Basedrive only)
ACL Ambient Cable, 3m with connector for CADM or PSM
AF5 Ambient Fibre (FC/APC, FC/APC)

Request A Price List of the full product range

Please note that you’ll receive one price list for all Cryo & Nano Positioning products!

Your name :
 

Contact details :
 

Please answer this question :

(We'll send the file to your e-mail address.)

RELATED PRODUCTS